Sale!

YCB8s-63PV DC MCB

Original price was: 720.00৳ .Current price is: 690.00৳ .

Technical data

Number of poles 1P 2P 3P 4P
Rated working voltage Ue (V) DC400  DC800 DC1000 DC1200 DC1500
Rated insulation voltage Ui(V) DC400 DC1000 DC1200 DC1500
Rated impulse withstand voltage Uimp (KV) 4
Rated current In(A) 20, 32,63
Ultimate short-circuit breaking capacity Icu (KA) Default:6;H:10
Instantaneous tripping characteristics B,C,K
Service life (times) Mechanical 20000,electrical life 1500
Protection degree IP20
Operating ambient temperature -25℃~+40℃
Altitude ≤2000m
Wiring  capacity(mm²) 25
Connection both upper and lower incoming lines are acceptable
Use Category A
Standard IEC60947-2
Category:

Description

Photovoltaic Miniature Circuit Breaker YCB8s-63PV DC MCB (polarity)

General
YCB8s-63PV photovoltaic dedicated DC circuit breaker is mainly used in solar photovoltaic power generation systems. The maximum working voltage can reach DC1200V, and the rated current is up to 63A. It is used for overload and short circuit protection of the line, and can quickly cut off the fault current of the DC distribution system, protecting the important components in the solar power generation system – photovoltaic modules from the harm of DC side reverse current and AC side feedback current caused by inverter faults, ensuring the reliable operation of the solar photovoltaic power generation system.
Standards:IEC60947-2

Type designation

Product name Shell frame Breaking capacity PV  DC Number of poles Rated current Operating voltage
YCB8s 63 H PVn 2P 20A DC600
YCB8s 63 Default:6KA
H:10KA
PVn:Photovoltaic DC non-polarity 1P
2P
3P
4P
1A
2A
3A
4A
6A
10A
16A
20A
25A
32A
40A
50A
63A
DC400V
DC800V
DC1000V
DC1200V
DC1500V

Technical data

Number of poles 1P 2P 3P 4P
Rated working voltage Ue (V) DC400  DC800 DC1000 DC1200 DC1500
Rated insulation voltage Ui(V) DC400 DC1000 DC1200 DC1500
Rated impulse withstand voltage Uimp (KV) 4
Rated current In(A) 1,2,3,4,6,10,16,20,25,32,40,50,63
Ultimate short-circuit breaking capacity Icu (KA) Default:6;H:10
Instantaneous tripping characteristics B,C,K
Service life (times) Mechanical 20000,electrical life 1500
Protection degree IP20
Operating ambient temperature -25℃~+40℃
Altitude ≤2000m
Wiring  capacity(mm²) 25
Connection both upper and lower incoming lines are acceptable
Use Category A
Standard IEC60947-2

Temperature correction factor table

Current correction value used in different environments
Rated current(A) Ambient temperature corresponding to rated current (A)
In(A) -25℃ -20°℃ -10°℃ 0℃ 10°℃ 20°℃ 30℃ 35℃ 40°℃ 50°℃ 60℃ 75°℃
6A 10.12 9.77 9.03 8.26 7.49 6.75 6 5.59 5.19 4.75 4.62 /
10A 17.41 16.75 15.41 14.04 12.71 11.35 10 9.09 8.21 7.9 8.7 7.86
16A 21.72 21.15 20.15 19.12 18.08 17.04 16 15.49 15.1 14.38 13.52 12.75
20A 25.86 25.79 24.61 23.47 22.32 21.16 20 19.43 18.83 18.58 17.1 16.3
25A 32.41 31.74 30.37 28.98 27.69 26.35 25 24.33 23.65 23.3 24.7 23.8
32A 44.83 43.62 41.29 38.96 36.67 34.33 32 30.83 29.67 30.7 30.8 30
40A 50.34 49.35 47.51 45.62 43.73 41.87 40 39.04 38.11 38.6 36.2 35.8
50A 63.79 62.48 59.99 57.48 54.98 52.5 50 48.76 47.48 47.1 47.5 46
63A 80 78.46 75.38 72.28 69.17 66.09 63 61.46 59.93 55.6 53.8 52.4

Reviews

There are no reviews yet.

Be the first to review “YCB8s-63PV DC MCB”