Sale!

Photovoltaic DC Surge Protective Device YCS8-S

Original price was: 1,790.00৳ .Current price is: 1,650.00৳ .

Technical data

Model YCS8-S
Standard IEC61643-31:2018; EN 50539-11:2013+A1:2014
Test category T1+T2 T2
Number of poles 2P 3P 3P 2P 3P 3P
Maximum continuous working voltage Ucpv 600VDC 1000VDC 1500VDC 600VDC 1000VDC 1500VDC
Maximum discharge current Imax(kA) 40
Nominal discharge current In(kA) 20
Maximum impulse current limp(kA) 6.25 /
Voltage protection level Up(kV) 2.2 3.6 5.6 2.2 3.6 5.6
Response time tA(ns) ≤25
Remote and indication
Working status/fault indication Green/red
Remote contacts Optional
Remote terminal
switching capability
AC 250V/0.5A
DC 250VDC/0.1A/125VDC 0.2A/75VDC/0.5A
Remote terminal connection capability 1.5mm²
Installation and environment
Working temperature range -40℃-+70℃
Allowable working humidity 5%…95%
Air pressure/altitude 80k Pa…106k Pa/-500m   2000m
Terminal torque 4.5Nm
Conductor cross section(maximum) 35mm²
Installation method DIN35 standard din-rail
Protection degree IP20
Shell material Fire-proof level UL 94 V-0
Thermal protection Yes
Category:

Description

General
YCS8-S series Photovoltaic DC Surge Protective Device  is applicable to photovoltaic power generation system. When surge overvoltage occurs in the system due to lightning stroke or other reasons, the protector immediately conducts in nanosecond time to introduce the surge overvoltage to the earth, thus protecting the electrical equipment on the grid.

Features

● T2/T1+T2 surge protection has two types of protection, which can can meet Class I (10/350 μS waveform) and Class II (8/20 μS waveform) SPD test, and voltage protection level Up ≤ 1.5kV;
● Modular, large-capacity SPD, maximum discharge current Imax=40kA;
● Pluggable module;
● Based on zinc oxide technology, it has no power frequency after current and fast response speed, up to 25ns;
● The green window indicates normal, and the red indicates a defect, and the module needs to be replaced;
● Dual thermal disconnection device provides more reliable protection;
● Remote signal contacts are optional;
● Its surge protection range can be from power system to terminal equipment;
● It is applicable to direct lightning protection and surge protection of DC systems such as PV combiner box and PV distribution cabinet.

 

Selection

YCS8 S I+II 40 PV 2P DC600 /
Model Types Test category Maximum
discharge
current
Use
category
Number
of poles
Maximum
continuous
working
voltage
Functions
SPD /: Standard type
S: Upgraded type
I+II: T1+T2 40: 40KA PV:
Photovoltaic/
direct-current
2: 2P DC600 /: Non
communication
R: Remote
communication
3: 3P DC1000
DC1500
II: T2 2: 2P DC600
3: 3P DC1000
DC1500

Reviews

There are no reviews yet.

Be the first to review “Photovoltaic DC Surge Protective Device YCS8-S”

Your email address will not be published. Required fields are marked *